Structure factors have been supplied for datablock(s) Cherif_BK7
No syntax errors found. CIF dictionaryStructure factor report
Please wait while processing .... Interpreting this report
| Bond precision: | C-C = 0.0032 A | Wavelength=0.71073 |
| Cell: | a=13.2178(5) | b=15.9264(7) | c=16.6112(7) |
| alpha=83.632(2) | beta=78.924(2) | gamma=75.508(2) | |
| Temperature: | 100 K |
| Calculated | Reported | |
| Volume | 3315.3(2) | 3315.3(2) |
| Space group | P -1 | P -1 |
| Hall group | -P 1 | -P 1 |
| Moiety formula | C24 H21 Cu2 N4 O12 P3, 2(H3 O4 P) | C24 H21 Cu2 N4 O12 P3, 2(H3 O4 P) |
| Sum formula | C24 H27 Cu2 N4 O20 P5 | C24 H27 Cu2 N4 O20 P5 |
| Mr | 973.45 | 973.42 |
| Dx,g cm-3 | 1.950 | 1.950 |
| Z | 4 | 4 |
| Mu (mm-1) | 1.621 | 1.621 |
| F000 | 1968.0 | 1968.0 |
| F000' | 1973.57 | |
| h,k,lmax | 19,23,24 | 19,23,24 |
| Nref | 21312 | 21231 |
| Tmin,Tmax | 0.777,0.837 | 0.726,0.850 |
| Tmin' | 0.772 |
| Correction method= # Reported T Limits: Tmin=0.726 Tmax=0.850 AbsCorr = MULTI-SCAN |
| Data completeness= 0.996 | Theta(max)= 31.090 |
| R(reflections)= 0.0382( 15937) | wR2(reflections)= 0.0939( 21231) | |
|
The following ALERTS were generated. Each ALERT has the format
test-name_ALERT_alert-type_alert-level.
Click on the hyperlinks for more details of the test.
Alert level C
PLAT911_ALERT_3_C Missing FCF Refl Between Thmin & STh/L= 0.600 3 Report
4 0 0, -1 1 1, -5 4 2,
PLAT977_ALERT_2_C Check Negative Difference Density on H39P . -0.38 eA-3
Alert level G
PLAT007_ALERT_5_G Number of Unrefined Donor-H Atoms .............. 22 Report
H2P H4P H6P H8P H11P H17P H18P H21P
H25P H27P H12P H13P H14P H28P H30P H31P
H32P H33P H34P H37P H38P H39P
PLAT154_ALERT_1_G The s.u.'s on the Cell Angles are Equal ..(Note) 0.002 Degree
PLAT480_ALERT_4_G Long H...A H-Bond Reported H1A ..O32 . 2.66 Ang.
And 7 other PLAT480 Alerts
More ...PLAT484_ALERT_4_G Round D-H..A Angle Rep for C1 ..O1 . 113 Degree
And 33 other PLAT484 Alerts
More ...PLAT790_ALERT_4_G Centre of Gravity not Within Unit-Cell: Resd. # 5 Note
H3 O4 P
PLAT790_ALERT_4_G Centre of Gravity not Within Unit-Cell: Resd. # 6 Note
H3 O4 P
PLAT794_ALERT_5_G Tentative Bond Valency for Cu1 (II) . 2.16 Info
And 3 other PLAT794 Alerts
More ...PLAT910_ALERT_3_G Missing FCF Reflection(s) Below Theta(Min)[Deg]= 1.32 Note
0 0 1,
PLAT912_ALERT_4_G Missing # of FCF Reflections Above STh/L= 0.600 73 Note
PLAT913_ALERT_3_G Missing # of Very Strong Reflections in FCF .... 1 Note
4 0 0,
PLAT969_ALERT_5_G The 'Henn et al.' R-Factor-gap value ........... 2.484 Note
Predicted wR2: Based on SigI**2 3.78 or SHELX Weight 9.27
PLAT978_ALERT_2_G Number C-C Bonds with Positive Residual Density. 10 Info
0 ALERT level A = Most likely a serious problem - resolve or explain
0 ALERT level B = A potentially serious problem, consider carefully
2 ALERT level C = Check. Ensure it is not caused by an omission or oversight
55 ALERT level G = General information/check it is not something unexpected
1 ALERT type 1 CIF construction/syntax error, inconsistent or missing data
2 ALERT type 2 Indicator that the structure model may be wrong or deficient
3 ALERT type 3 Indicator that the structure quality may be low
45 ALERT type 4 Improvement, methodology, query or suggestion
6 ALERT type 5 Informative message, check
|
Publication of your CIF
You should attempt to resolve as many as possible of the alerts in all categories. Often the minor alerts point to easily fixed oversights, errors and omissions in your CIF or refinement strategy, so attention to these fine details can be worthwhile. In order to resolve some of the more serious problems it may be necessary to carry out additional measurements or structure refinements. However, the nature of your study may justify the reported deviations from journal submission requirements and the more serious of these should be commented upon in the discussion or experimental section of a paper or in the "special_details" fields of the CIF. checkCIF was carefully designed to identify outliers and unusual parameters, but every test has its limitations and alerts that are not important in a particular case may appear. Conversely, the absence of alerts does not guarantee there are no aspects of the results needing attention. It is up to the individual to critically assess their own results and, if necessary, seek expert advice. If you wish to submit your CIF for publication in Acta Crystallographica Section C or E, you should upload your CIF via the web. If you wish to submit your CIF for publication in IUCrData you should upload your CIF via the web. If your CIF is to form part of a submission to another IUCr journal, you will be asked, either during electronic submission or by the Co-editor handling your paper, to upload your CIF via our web site. |
| Datablock Cherif_BK7 - ellipsoid plot |
|